RLD - SERIES

 

The Energic Plus - RLD Series is composed by two traction battery chargers with THREE-PHASE input: RLD-A and RLD-B.

Each model covers a different power range, while the control and safety features are the same for all the chargers of this series.

The manufacturer is available for custom and OEM productions.

 

 

RLD-A

RLD.jpg (25748 byte)

CLICK HERE TO ZOOM ON THE DISPLAY

CE and EMC certified products         ISO 9000:2000

 

 

FEATURES

  • Fully automatic;
  • Microprocessor controlled electronic card;
  • Digital display, with cyclical indication of charge status: VOLTAGE/CELL, CHARGE CURRENT, CAPACITY RETURNED TO THE BATTERY, TIME OF CHARGE, STATE OF CHARGE AND EQUALIZATION, ERROR MESSAGES. CLICK HERE TO ZOOM ON THE DISPLAY;
  • Charge time calculation with exclusive dV/dT-3Q system, for maximum battery life and performance. Please contact the manufacturer for details;
  • Safety timer for emergency shutdown;
  • Independent safety circuit, for absolute protection of the battery against overcharge, also in case of fault of the microprocessor;
  • Faulty condition visualization;
  • Automatic equalization system;
  • Automatic battery maintenance function, useful to keep the battery in perfect condition when it's not used for long time;
  • Automatic start on battery connection;
  • Automatic shutdown on battery disconnection;
  • 3 seconds delay on start (to avoid sparks between the connectors);
  • Automatic data saving in case of main supply black-out and automatic resume from the exact point of interruption; 
  • Multivoltage design: one card fits in all chargers;
  • Open software: our engineers can easily add new features for custom applications;
  • 3 years full warranty;
  • Protection index IP20;
  • Charge curve Wa (DIN41774);
  • Charge curve WoWa (DIN41773) available;
  • Three-phase input: 220/380V;
  • Transformer taps for input voltage adjustment;
  • External size mm 500 x 360 x 700;
  • CE mark.

 

STANDARD MODELS

VOLTAGE
(Volt)
CURRENT
(Ampere)
BATTERY CAPACITY
(Ah)
WEIGHT
(kg)
INPUT POWER
(kVA)
24 60 360 57 2,1
24 80 480 62 2,8
24 100 600 66 3,5
24 120 720 68 4,2
24 140 840 76 4,9
36 60 360 59 3,1
36 80 480 64 4,2
36 100 600 73 5,2
36 120 720 81 6,2
40 50 300 45 4,4
40 60 360 49 5,3
40 80 480 57 7,0
48 50 300 60 2,8
48 60 360 66 4,2
48 80 480 75 5,6
48 100 600 82 7,0
48 120 720 89 8,4
72 60 360 80 6,3
72 80 480 88 8,3
80 60 360 81 6,9
80 80 480 93 9,2

 

 

RLD-B

RLD.jpg (25748 byte)

CLICK HERE TO ZOOM ON THE DISPLAY

 

CE and EMC certified products         ISO 9000:2000        

 

 

FEATURES

  • Fully automatic;
  • Microprocessor controlled electronic card;
  • Digital display, with cyclical indication of charge status: VOLTAGE/CELL, CHARGE CURRENT, CAPACITY RETURNED TO THE BATTERY, TIME OF CHARGE, STATE OF CHARGE AND EQUALIZATION, ERROR MESSAGES.  CLICK HERE TO ZOOM ON THE DISPLAY;
  • Charge time calculation with exclusive dV/dT-3Q system, for maximum battery life and performance. Please contact the manufacturer for details;
  • Safety timer for emergency shutdown;
  • Independent safety circuit, for absolute protection of the battery against overcharge, also in case of fault of the microprocessor;
  • Faulty condition visualization;
  • Automatic equalization system;
  • Automatic battery maintenance function, useful to keep the battery in perfect condition when it's not used for long time;
  • Automatic start on battery connection;
  • Automatic shutdown on battery disconnection;
  • 3 seconds delay on start (to avoid sparks between the connectors);
  • Automatic data saving in case of main supply black-out and automatic resume from the exact point of interruption; 
  • Multivoltage design: one card fits in all chargers;
  • Open software: our engineers can easily add new features for custom applications;
  • 3 years full warranty;
  • Protection index IP20;
  • Charge curve Wa (DIN41774);
  • Charge curve WoWa (DIN41773) available;
  • Three-phase input: 220/380V or 208/240/480V or 600V, 50/60Hz;
  • Transformer taps for input voltage adjustment;
  • External size mm 500 x 440 x 900;
  • CE mark.

STANDARD MODELS

VOLTAGE
(Volt)
CURRENT
(Ampere)
BATTERY CAPACITY
(Ampere-hours)
WEIGHT
(kg)
INPUT POWER
(kVA)
24 160 960 77 5,6
24 200 1200 -- 7,0
36 140 840 86 7,3
36 160 960 95 8,4
48 140 840 99 9,8
48 160 960 113 11,2
48 200 1200 132 14,0
72 100 600 94 10,5
72 120 720 113 12,5
72 140 840 122 14,6
80 100 600 105 11,5
80 120 720 117 13,8
80 140 840 124 16,1
80 160 960 129 18,4
80 200 1200 150 23,0
96 100 600 118 14,0
96 120 720 123 16,8
96 140 840 140 19,6
96 160 960 148 22,4
96 240 1440 198 33,6
96 320 1920 252 44,8
 

BACK TO PRODUCTS PAGE

 

CE and EMC certified products         ISO 9000:2000        